Send request
In this video, we will talk about the most common mistakes when installing a breakaway coupling, and also show how to install it correctly, using the example of the Hydrosila breakaway coupling.
Some people screw the breakaway coupling with a fitting to the tractor chassis, which is fundamentally wrong. Others install it between high-pressure hoses and make the exact same mistake.
Correct installation of the breakaway coupling during emergency disconnection of trailed or mounted implements from the machinery will save the high-pressure hoses and prevent the leakage of expensive oil from the hydraulic system.
Correct installation of the breakaway coupling helps to preserve high-pressure hoses and expensive working fluid in the hydraulic lines.